- Product code:
- 119970 / 119971
- Applications:
- Fire OEMs, Firefighting - Airport (ARFF), Firefighting - Industrial, Firefighting - Structural, Firefighting - Wildland Forestry
Technical details & documents
For the Twister Electronic Throttle
To view all document login to your account
Can Specification | SAE J1939: 125, 250, 500 Kbits/second |
---|---|
Brand | Hale Products |
Application Solutions | Fire OEMs, Firefighting - Airport (ARFF), Firefighting - Industrial, Firefighting - Structural, Firefighting - Wildland Forestry |
Overview Table |
|
Environmental Range | IP 67 |
Temperature Range (Metric) | -30C ... +85C |
Volts | +9 VDC ... +32 VDC |
Weight (Imperial) | 22.8 oz |
Weight (Metric) kg | 646.4 g |
Width (English) | 4.438" |
Width (Metric) | 112.73mm |
Depth (English) | 2.312" |
Depth (Metric) | 58.74mm |
Height (English) | 3.188" |
Height (Metric) | 80.98mm |
Amperage | 240 mA (13.8 VDC) / 163 mA (27.6 VDC) |
Engine Power | $0.00 |
Temperature range
- -40ºC…+85ºC
Electrical protection
- Internal thermal fuse
- Reverse voltage protection
- CAN buses protected to 24V
- ESD voltage protected to SAE J1113 specification for heavy duty trucks (24V)
- Transient voltage protected to SAE J1113 specification for heavy duty trucks (24V)
- Load dump voltage protected to SAE J1113 specification for heavy duty trucks (24V)
Electrical performance
Environmental performance
- Thermal shock. SAE J1455 (sec 4.1.3.2)
- Exposure to humidity. MIL-STD-810F (method 507.4)
- Thermal shock due to splash Class 1 (STD-0001) Pressure cleaning. SAE J1455 (sec 4.4)
- Exposure to salt spray atmosphere/fog. SAE J1455 (sec 4.3)
- Exposure to outdoor UV. ISO 4892-2 (method A)
Mechanical performance
- Resonance dwell. SAE J1455 (sec 4.9.4.1)
- Random vibration. SAE J1455 (sec 4.9.4.2)
- Mechanical shock. SAE J1455 (sec 4.10.3.4)